Temperature Measurement via Thermocouple

This is a temperature measurement circuit using thermocouple. This is a low-frequency application. It will allow the OPA335 to be switched directly into the signal path. This circuit has low noise, high accuracy, and low drift. Here is the circuit :

Temperature Measurement via Thermocouple circuit schematic diagram

The 4.096-V bridge supply is provided by a precision voltage reference. A negative temperature coefficient of  diode D1′s forward voltage is -2 mV/ºC. It also provides cold junction compensation via the resistor network R1 to R3. R6 is used to obtain the zero adjustment for a defined minimum temperature. The gain for the output amplifier is set by R8 and R7.

This circuit has 16-bit or better accuracy at high gain in low-voltage applications because the single-supply amplifier provide an open loop gain of 130dB. This circuit has an auto zeroing, that is used to provide typical values of 1 µV of input offset and 20 nV/ºC of offset drift over temperature and  remove 1/f noise. [Source: Texas Instruments Application Note]

This entry was posted in Test and Measurement and tagged . Bookmark the permalink.,

Possibly Related to "Temperature Measurement via Thermocouple" Circuits

  • Micropower Single-Supply Instrumentation Amplifier
    A schematic diagram of a micropower single-supply instrumentation amplifier circuit is shown below. This circuit only need 15µA of current and can give over 110dB of common rejection. A single amplifier can provide differential to single-ended conversion with excellent common … Continue reading →...
  • Precision Current Loop Thermocouple Transmitter
    Current loop analog data transmission is used in industrial environment because of its robustness (good noise immunity), while providing wiring fault detection (short and broken wiring) with a simple mechanism by detecting out range current level. In 4-20mA current loop … Continue reading →...
  • Thermocouple Cold Junction Compensation (Compensation for Grounded Thermocouple)
    Cold junction error in thermocouple can be seen as an offset drift that depend on the cold junction temperature. we can use the following circuit to correct this error for grounded thermocouple configuration: Adjustments: compensates for both sensor and resistor … Continue reading →...
  • SOT Temperature Sensors with Period/Frequency Output
    This is a low-current temperature sensors with a single-wire output. The number of pins that needed to interface with a microprocessor is minimized by this circuit because it uses a single-wire output. This circuit can be used in many appplication … Continue reading →...
  • Type K Thermocouple Amplifier And Cold Junction Compensator
    The output conditions of a Type K thermocouple, while providing cold-junction compensation, operating over temperatures between 0′C and 250′C is shown in circuit diagram below. This circuit has been designed to produce a basic output voltage transfer characteristic of 10mV/’C … Continue reading →...

Comments are closed.